大庆石化分公司炼油厂延迟焦化装置低温水-顶循换热器投用13个月,管束发生腐蚀穿孔。对换热器管束进行取样,从管体内壁腐蚀状况、管体材质金相组织、管体内壁涂层状态以及工艺操作几方面对泄漏原因进行了分析。根据分析结果,提出处理措施。目前换热器已完好运行4 a,证明该处理方式可行,效果显著。
Daqing Petrochemical Branch refinery delayed coking unit low temperature water - top heat exchanger used for 13 months, the tube bundle corrosion perforation. The tube bundle of the heat exchanger was sampled, and the causes of the leakage were analyzed from the corrosion status of the inner wall of the pipe body, the microstructure of the pipe body, the coating state of the inner wall of the pipe body and the operation of the process. According to the analysis results, put forward the handling measures. At present, the heat exchanger has been in good operation for 4 years, proving that the treatment is feasible and the effect is remarkable.