目的:分析脉动真空压力蒸汽灭菌湿包的原因及控制措施,以保证物品灭菌效果。方法:根据《消毒技术规范》湿包评判标准,对1026炉次计46830个灭菌包进行观察分析。结果:发现湿包97个,湿包率0.21%,冷却方式不正确和包装方法不规范是造成湿包的主要原因。结论:加强人员培训,规范包装方法,进行合理装载和正确的卸载可有效控制湿包的发生。
OBJECTIVE: To analyze the causes and control measures of pulsating vacuum pressure steam sterilization wet bag in order to ensure the sterilization effect of articles. Methods: According to the standard of wet sterilization in “Technical Specifications of Disinfection”, 46830 sterilization packs in 1026 furnaces were observed and analyzed. Results: 97 wet packs were found with a wet pack rate of 0.21%. Incorrect cooling methods and irregular packaging methods were the main reasons for wet packs. Conclusion: Strengthening personnel training, standardizing the packaging method, carrying out proper loading and correct unloading can effectively control the occurrence of wet packs.