我矿化验室原用通风柜排毒时,因酸气直接通过风机和风管,不仅使其受严重腐蚀,而且酸气容易扩散到整个化验室,严重影响化验人员的身体健康。为此,我们将原排毒方式改为喷咀引射方式,取得良好效果。喷咀引射排毒系统见附图。加工样品时,开动风机1,风流经风管2从喷咀3喷出,在通风柜出风管4内造成负压,使通风
When I used to detoxify the original fume hood of the mineralized laboratory, the sour gas directly passed through the fan and the air duct, which not only made it seriously corroded but also sour gas could easily spread to the entire laboratory, seriously affecting the health of laboratory personnel. To this end, we will be the original detoxification nozzle injection method, and achieved good results. Nozzle ejection detoxification system see attached map. When processing the sample, the fan 1 is started and the air flow is ejected from the nozzle 3 through the air duct 2 to create a negative pressure in the air duct 4 of the fume hood so that ventilation