论文部分内容阅读
本文主要根据展览馆项目的负荷计算结果确定了空调冷热源系统的形式,同时简要地介绍了空调末端系统及生活热水系统的形式。接着确定了各类负荷需求下地源热泵机组及泳池除湿热泵机组的联合运行方式,同时根据全年累计冷热负荷计算结果,分析地源热泵系统的地热平衡情况,进一步优化系统运行的方式。
This paper mainly based on the load calculation results of the exhibition hall project to determine the form of air conditioning system, at the same time a brief introduction to the end of the air conditioning system and domestic hot water system. Then, the joint operation mode of ground source heat pump units and swimming pool dehumidification heat pump units under various load demands is determined. At the same time, the geothermal balance situation of ground source heat pump system is analyzed and the way of system operation is further optimized.