【摘 要】
:
We present a high-sensitivity fiber Bragg grating (FBG)-based microphone with a flat response and static pressure equalization. A very high dynamic sensitivity of the microphone is achieved by a pressure sensing structure based on a carbon fiber diaphragm
【机 构】
:
ShandongKeyLaboratoryofOpticalFiberSensingTechnologies,LaserInstitute,QiluUniversityofTechnology(Sha
【出 处】
:
ChineseOpticsLetters
论文部分内容阅读
We present a high-sensitivity fiber Bragg grating (FBG)-based microphone with a flat response and static pressure equalization. A very high dynamic sensitivity of the microphone is achieved by a pressure sensing structure based on a carbon fiber diaphragm. Static pressure equalization is realized by a balance structure with a capillary glass tube. The resonances of the sensor are suppressed by air damping structures, and a broadened flat response is achieved. An acoustic-solid interaction model was used to analyze the response characteristics of the microphone. An experimental prototype was produced and tested, and the results are well consistent with the design. The tested sensitivity was 10 dB re 1 pm/Pa from 10 Hz to 2.5 kHz with a fluctuation of less than ±1.5 dB. Combined with the phase-generated-carrier-based coherent detection scheme, the microphone can achieve a sound resolution of the milli-pascal level. The static pressure sensitivity is measured to be 0.27 pm/atm, which is 100 dB lower than the dynamic sensitivity.
其他文献
光动力学治疗鲜红斑痣(PWS)目前被认为是较为有效的一种新型诊疗技术。治疗过程中光能量在皮肤中的分布情况对理解、预计和改进鲜红斑痣的临床治疗效果有重要的作用。基于人体皮肤的组织结构、鲜红斑痣的病理特征、光在皮肤组织中的传输特性以及皮肤各层的组织光学参数, 建立了一种具有多层组织结构的鲜红斑痣皮肤光学模型, 介绍了该模型中组织光学参数的确定方法。利用蒙特卡罗方法结合临床数据计算了光能量在鲜红斑痣皮肤中随深度的分布, 结果可为临床上如何选择最佳光剂量提供部分参考依据。利用本模型做进一步的详细完整的计算可以为光
在实验上首次研究了冷电离的纯一氧化碳脉冲激光器的阈值、动力学、时间、光谱等的特性。在工作气体的温度~100 K和密度达1.0阿码下以有效体积~5升进行了实验。激发的持续时间在30~300微秒内变化。在5.1~5.5微米的光谱区中观察到振荡,当增加泵浦能量时,光谱向短波区增宽。证明纯一氧化碳的电子电离CO激光效率不超过10%。发现电离CO激光器的测量参数与理论计算结果不相符合。
研究了实时高精度激光光斑检测方法。利用高帧频、高灵敏度CCD采集14位激光光斑视频;分析了激光光斑的特征,在使用阈值分割出光斑区域后,通过上三邻域连续点计数算法检测了激光光斑区域;分析了激光光斑中余光斑存在的原因,利用平均阈值法滤除了余光斑,在剩余的主光斑中计算获得了更为精确的光斑中心(含质心与形心),制定了以参考帧为基准的视频帧序列的操作序列法光斑检测流程,解决了传统相邻帧相减法无法检测逆光斑帧及光斑中心位置不同的连续相邻光斑帧的问题。实验结果表明,算法可实践用于在线实时与离线实时的高精度激光光斑检测。
对1550nm高功率窄线宽光纤放大器进行了实验研究。该放大器采用双级放大(MOPA)结构, 其中第一级预放采用5 m长的掺Er3 光纤, 将种子光信号放大到约90 mW; 采用15 m长的Er3 /Yb3 共掺双包层光纤放大器作为二级放大, 抽运源采用2支工作波长为980 nm的大功率激光二极管(LD), 抽运阈值功率约1.3 W。 当抽运功率为10.8 W时, 得到放大激光输出功率为1.97 W, 光-光转换效率为18 %, 斜率效率为21%, 增益大于13 dB。所采用的种子光源为1550 nm单频窄
A multi-GPU system designed for high-speed, real-time signal processing of optical coherence tomography (OCT) is described herein. For the OCT data sampled in linear wave numbers, the maximum processing rates reached 2.95 MHz for 1024-OCT and 1.96 MHz for
利用发光二极管(LED)的高速发光特性,以旋转的二维发光二极管阵列为显示载体,通过时分寻址电路快速显示三维形体的二维截面序列。受调制的离散二维图像信息,因视觉暂留而形成深度效应,将被整合感知为一幅连续的三维图像。成功实现了具有49152个体像素,尺寸为φ144.6 mm×110 mm的柱体空间内的三维显示,图像具有双目视差、调节、会聚等常规视差信息,能提供真实的深度暗示,可同时从任意角度直接观察。论述了系统的显示原理及图像编码分解方法,分析和讨论了显示质量与体像素优化选取、起始位置显示信息的关联程度。
Pumped by rectangular-shaped dissipative soliton resonance (DSR) pulses at 1030 nm, selective excitations of Raman Stokes lines of up to third order with extinction ratios of 8 dB and fifth order with extinction ratios of 4 dB are demonstrated experimenta
法国通用电气研究中心宣布,他们发现了到目前为止最短的可见激射光谱线(以前未报导过)。
In this work a passively Q-switched dual-wavelength ytterbium-doped fiber laser using
结构光平面标定是结构光三维视觉测量中的重要环节。传统的标定方法需要昂贵的设备,效率低下,步骤复杂。提出了一种新的三维视觉系统中结构光平面的标定方法。该方法仅使用一个简单的二维平面靶标,在保证靶标与结构光相交的前提下,靶标在摄像机可视范围内自由移动数个位置。对于移动到各个位置的靶标平面,分别建立对应的世界坐标系,并计算该世界坐标系与摄像机坐标系、图像坐标系的转换关系。通过处理算法,可以将每一个位置得到的结构光平面与靶标平面的交线方程统一到摄像机坐标系下。使用最小二乘法拟合多条交线可以标定出结构光平面在摄像机