考虑温度影响对钢框架进行屈曲分析,以评估火灾下柱的屈曲长度。将得到的屈曲长度与EC3中消防部分(第1.2节)所给出的值进行比较,该部分用于火灾情况下有支撑框架柱的设计。EC3第1.2节并没有给出无支撑框架屈曲长度的消防设计准则,因此,该研究给出了无支撑钢结构中柱的屈曲长度。将火灾情况下若干不同框架的力学抗力计算结果(利用简单模型计算)和估算的屈曲长度与高级模型的计算结果进行了对比。
The buckling analysis of the steel frame considering the influence of temperature is carried out to evaluate the buckling length of the column under fire. The resulting buckling length is compared to the value given in the fire protection section of EC3 (Section 1.2), which is used for the design of a supported frame column in a fire situation. EC3 Section 1.2 does not give the design criteria for fire protection for unsupported frame buckling lengths. Therefore, the study gives the buckling length of the column in unsupported steel structures. The results of mechanical resistance (using simple model calculation) and the estimated buckling length for several different frames in fire cases are compared with those of the high-level model.