论文部分内容阅读
目的分析消毒剂在使用中有效含量变化情况,指导消毒剂的配制与使用。方法采集医院使用中消毒剂,检测其中的有效含量。结果使用中消毒剂有效含量实测值与标示值相符的占12.79%,高于标示值的占43.02%;低于标示值的占44.19%。平均降低幅度和高出幅度分别为29.24%和63.77%。结论消毒剂在配制和使用过程中存在很大问题,应加强消毒剂浓度的日常监测。
Objective To analyze the changes of the effective content of disinfectants in use and to guide the formulation and use of disinfectants. Methods The hospital disinfectant was collected to detect the effective content. Results The effective content of the disinfectant in use was 12.79% of the indicated value, 43.02% higher than the indicated value and 44.19% of the indicated value. The average reduction rate and the high range were 29.24% and 63.77% respectively. Conclusion Disinfectants in the preparation and use of the process there is a big problem, should strengthen the daily monitoring of disinfectant concentration.