Long-term clinical outcomes after bioabsorbable polymer-and durable polymer-based sirolimus-eluting

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:xianglikai
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Several clinical trials have shown that sirolimus-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The FIREBIRD stent (coated with durable polymer) and the EXCEL stent (coated with bioabsorbable polymer) are two different types of sirolimus-eluting stents made in China; both have been approved for clinical use in China by the State Food and Drug Administration. The mid-term (6-month) angiographic and clinical results of both stents have been confirmed exciting perspective outcomes. However, it is unclear whether there are differences in the long-term safety and efficacy between the two types of stents in daily practice.Methods All consecutive patients undergoing elective PCI with EXCEL or FIREBIRD stents between June 1,2006 and December 31, 2006 at Fu Wai Hospital in Beijing were included. Patients were classified from the index admission according to stent types (EXCEL or FIREBIRD) used. Clinical and procedural risk factors were collected prospectively. With propensity score matching without replacement, the frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target vessel revascularization) and stent thrombosis during a 2-year follow-up period were compared between the two groups.Results A total of 474 patients were treated with EXCEL, and 640 were treated with FIREBIRD. Three hundred and ninety-seven EXCEL patients were matched to 397 FIREBIRD patients, 2-year risk-adjusted MACE rates were 6.1% in EXCEL group and 7.6% in FIREBIRD group (HR 0.84, 95%CI 0.50-1.43), whereas the respective rates for mortality, myocardial infarction and target-vessel revascularization were 2.3% vs 2.8% (FIR 0.74, 95%CI 0.30-0.85), 1.8% vs 1.3% (HR 1.41,95%CI 0.45-4.43) and 2.5% vs 4.0% (HR 0.62, 95%CI 0.28-0.37), respectively. Cumulative incidence of stent thrombosis at 2 years was 1.8% in the EXCEL group vs 1.3% in the FIREBIRD group (P=0.5610), whereas the rate of very late stent thrombosis was 0.5% vs 1.3% (P=0.2550).Conclusions Results from this long-term, relatively large size, single-center study showed that both of the EXCEL and the FIREBIRD sirolimus-eluting stent had similar and lower incidence of MACE after PCI in daily practice.
其他文献
Background The incidence of no reflow phenomenon limits the clinical outcomes of percutaneous coronary intervention (PCI). This randomized controlled study was
课堂教学是动态发展的过程.一堂课的效果是各种因素的综合体现,对一堂课质量高低的评价,主要取决于整体教学效果.要适应新标准、不死搬硬套,执行新标准、不牵强附会.教无定法
以国际上最新的高频疲劳检测技术在铁路应用为基础,研究其在高速重载铁路上应用。通过德国高铁事故的启示,分析我国高铁和重载铁路金属疲劳可能产生的安全风险,列举了疲劳检
阐述ATP(Automatic Train Protection)设备在高铁事业中扮演的重要角色,剖析当前ATP故障原因及类型以确立课题研究方向,通过研制D电缆固定支架达到改善当前ATP设备运行质量的
采用航空涂料行业常用的试验设备和方法,对航空飞行器外蒙皮用新型色漆/清漆涂层系统与常规涂层系统两者之间的装饰性、单位面积质量、户外耐久性以及施工效率等进行对比试验
在采用高强复合树脂基新材料解决了施工便梁扣件绝缘问题的同时,对既有系统构造等存在的问题,有针对性地制定改进方案,以此提高扣件整体系统的精密性和可靠性,确保轨道结构稳
目的寻找上呼吸道感染防治的有效措施,从而提高体系部队战斗力。方法统计分析我院2007年度病例库,挖掘出有价值的规律。结果通过有针对性的政策干预,降低上呼吸道感染发病率
对P95大修列车龙门架齿轮箱走行装置进行国产化研制。介绍了其设计参数、结构特点、关键零部件的设计计算及台架试验等。经过装车使用,运行良好,对同类产品的国产化研制具有