论文部分内容阅读
结合工程实例,对渗滤取水技术在海水源热泵系统中应用的技术和经济性进行了探讨,结果显示,渗滤取水系统能为热泵系统提供水质好且夏季水温较低和冬季水温较高的海水;采用渗滤取水系统的海水源热泵空调系统无论在初投资还是运行费用上都优于直接利用地表海水的海水源热泵空调系统和传统的冷水机组加城市热网系统。
Combined with the engineering examples, the technology and economy of applying leachate water extraction technology to seawater source heat pump system are discussed. The results show that the percolation water intake system can provide heat pump system with good water quality and low water temperature in summer and high water temperature in winter Seawater source heat pump air conditioning system using percolation and water intake system is better than the seawater source heat pump air conditioning system and conventional chiller plus heat network system directly using surface seawater in the initial investment or operation costs.