论文部分内容阅读
针对目前现有房间空调器在潮湿地区使用时,因其除湿量不足而不能很好地创造出室内舒适性环境这一问题,提出在不改变房间空调器原有配置的压缩机、冷凝器、蒸发器及毛细管的情况下,加上重力式热管换热器,可以显著地增加空调器的除湿量,并使空调器的出风温湿度适宜,而空调器的制冷量和功耗基本不变;所需的重力式热管换热器换热面积不超过蒸发器换热面积的2倍;重力式热管换热器在空调器上布置可行.
In view of the problems existing in the existing room air conditioners in wet areas, the lack of dehumidification capacity can not create a comfortable indoor environment, and proposes a compressor and a condenser that do not change the original configuration of the room air conditioner. In the case of evaporators and capillary tubes, the addition of a gravity-type heat pipe heat exchanger can significantly increase the dehumidification capacity of the air conditioner and make the temperature and humidity of the air conditioner suitable, while the cooling capacity and power consumption of the air conditioner are basically the same. The required heat transfer area of the gravity heat pipe heat exchanger does not exceed 2 times the heat exchange area of the evaporator; the gravity heat pipe heat exchanger is arranged on the air conditioner.