论文部分内容阅读
我厂3×10~4/a 汽油加氢装置的原料泵,是利用库存积压的西德 KSB 公司产品,型号HDAR-80/12.由于泵的参数与装置要求不符,试车中电机电流超标,使开工受阻。我厂采用去掉三级叶轮的方法,取得了很好的效果。1.库存泵参数库存泵为垂直剖分式的12级离心泵,原输送液化石油气,密度0.54 kg/dm~3,操作温度20℃,流量40~50m~3/h,总扬程800m,转速2975r/min,轴功率107kW,电机功率132kW。2.试运中的问题按装置开工要求,第一步水氮联送,输送水;第二步热油氮联运,输送煤油,第三步化工投料,输送汽油,是正常生产所输送的介质。
The raw material pump of 3 × 10 ~ 4 / a gasoline hydrogenation unit in our factory is the product of West Germany KSB which uses the backlog of stock, type HDAR-80 / 12. Because the parameters of the pump are inconsistent with the requirement of the device and the motor current in the test exceeds the standard, To start blocked. I plant removed three-stage impeller method, and achieved good results. 1. Stock pump parameters The stock pump is a vertical split type 12-stage centrifugal pump, the original delivery of liquefied petroleum gas, density 0.54 kg / dm ~ 3, operating temperature 20 ℃, flow 40 ~ 50m ~ 3 / h, Speed 2975r / min, shaft power 107kW, motor power 132kW. 2. The question of trial operation According to the requirements of equipment start-up, the first step is to send water and nitrogen together to transport water. The second step is to transport the coal and oil together by nitrogen and nitrogen, and the third step of chemical feeding and transportation of gasoline is the medium delivered by normal production .